Drift Eliminator Manufacturer

Cooling Tower Drift Eliminators - PVC, PP & FRP

Drift eliminators are devices used to capture these water droplets, they are usually made of plastic (PVC). Drift eliminators are like nets that catch these droplets and keep them inside the tower, helping save water and protect nature. Accent's drift eliminators feature low drift rates, often as low as 0.002 to 0.005% of the recirculating water flow rate. As one of the top drift eliminator manufacturers, suppliers in Mumbai India, we offer reliable solutions for cooling towers.

We manufacture premium-quality PVC Drift Eliminator, PP, and FRP models engineered to reduce water carryover, improve airflow management, and enhance cooling tower performance.

A Cooling Tower Drift Separator is an important component that captures tiny water droplets carried by the air stream during cooling tower operation. Without an effective Water Drift Control System, these droplets can result in water wastage, chemical carryover, scaling around equipment, and environmental impact.

Area of Application

The Accent Drift Eliminator series is ideal for applications that require large, site-erected Counterflow or Crossflow Cooling Towers.
  • Design Types:
    1. Counterflow
    2. Crossflow
  • Types of Cooling Towers
    1. FRP Cooling systems
    2. RCC Cooling Towers
    3. FRP Cooling Tower systems
    4. Treated Timber Towers
  • Types of Drift Eliminators Available
    1. C Type Drift Eliminator
    2. S Type Drift Eliminator
    3. Spectra Type Drift Eliminator
    4. Cellular Drift Eliminator
    5. Blade Type Drift Eliminator
  • Material
    1. PVC, PP, FRP

Cooling towers lose water in two ways

  • Evaporation: Water turns into vapor and escapes harmlessly.
  • Drift: Tiny water droplets are carried away by the air. if contains chemicals, might have a negative impact on the ecosystem.

Accent manufactures durable and efficient PVC, PP, and FRP Drift Eliminators for cooling towers that effectively remove particles from the air stream with minimal pressure loss, reducing fan power consumption. The eliminators release air at an angle atleast 40° from the horizontal, to ensure optimal cooling tower performance and reducing energy losses.

Our Cellular Drift Eliminator models are widely preferred for applications requiring high drift removal efficiency and compact design.

Similarly, the Blade Type Drift Eliminator is commonly used in cooling towers where controlled airflow and reduced pressure drop are important.

The purpose of Drift eliminator is to reduce the drift loss in the cooling tower. Drift eliminators normally kept next to fills in the air flow path thereby reducing the drift loss. Drift loss is the loss of entrained water through the hot air to atmosphere. Drift eliminators normally made up of PVC. More number of passes through drift eliminator decreases the drift loss but increases the pressure drop thereby increasing fan power consumption. And the Drift eliminator coming in C Type. S Type. Spectra type.